How Struxt3D designs to the National Structural Code of the Philippines 2015: 203.3.1 combinations, Section 207 wind, the Section 208 zone spectrum, ACI and AISC checks.

Level IntermediateTime 15 minCodes NSCP 2015Updated
Follow along in Struxt3DOpens the Multi-storey frame template with its default sizes.
Open the template

The National Structural Code of the Philippines 2015 (NSCP 2015, 7th edition, Volume 1) is the structural code for buildings in the Philippines. It has its own load chapters — combinations (203), live loads (205), wind (207) and earthquake (208) — and adopts the American material standards for design: ACI 318-14 for concrete (Chapter 4) and AISC 360-10 for steel (Chapter 5). Choosing NSCP 2015 in Struxt3D applies the NSCP load rules and runs the members through the ACI and AISC engines. This tutorial shows each rule, works a typical Metro Manila example and lists what you must still check.

Members, connections, walls, footings and composite beams are checked with the ACI 318-19 and AISC 360-22 equations that Struxt3D implements. These are the later editions of the standards NSCP 2015 adopts; the basic strength equations are the same, and the design results show this note so it appears in your report.

What Struxt3D takes from NSCP 2015

NSCP sectionTopicUsed for
203.3.1 (eqs. 203-1 to 203-7)Load combinationsStrength combinations with f1 and H
205, Tables 205-1, 205-3Live loadsFloor, roof and deck live loads
207 (Figure 207A.5-1)Wind3-s gust basic wind speed
208, Tables 208-2 to 208-8, 208-11EarthquakeZone Z, soil profile, near-source Na and Nv, Ca and Cv, R
Chapter 4 (ACI 318-14)ConcreteBeams, columns, slabs, walls, footings
Chapter 5 (AISC 360-10)SteelMembers (504 for cables), connections

Load combinations (203.3.1)

CombinationNSCP eq.
1.4D (+ 1.4H)203-1
1.2D + 1.6L (+ 1.6H)203-2
1.2D + 1.0W + f1L203-4
0.9D + 1.0W (+ 1.6H)203-6
1.2D + 1.0E + f1L203-5
0.9D + 1.0E (+ 1.6H)203-7
D + L (service)deflections

f1 is 1.0 for floors with a live load over 4.8 kPa (and for garages and places of public assembly) and 0.5 otherwise. Struxt3D sets it from the floor use: storage (6.0 kPa) gets 1.0, the other uses 0.5, and the combination name shows the value used, for example 1.2D + 1.0W + 0.5L. H, the earth pressure on retaining walls, is factored 1.6 (1.4 in eq. 203-1). Wind and earthquake are at strength level. Each wind combination is made for four directions, and each earthquake combination for ±(EX + 0.3EY) and ±(0.3EX + EY).

Live loads (205)

UseL (kPa)f1
Office2.40.5
Residential1.90.5
Retail4.80.5
Storage6.01.0
Roof1.0—
Footbridge deck (NSCP Vol. 2 / AASHTO LRFD 3.6.1.6)4.3—

Wind (207)

NSCP 2015 follows the ASCE 7-10 method with a 3-second gust basic wind speed from the contour maps of Figure 207A.5-1. The default is 69 m/s (250 km/h), a typical value; areas on the eastern seaboard can be higher and parts of Mindanao lower, so read the map for your site and occupancy category.

q = 0.613 Kz V² G, Kz = 2.01 (z/274)2/9.5 (exposure C), G = 0.85z at least 4.6 m. Walls: 0.8q windward, 0.5q leeward. Kzt = Kd = 1.0.

Earthquake (208)

NSCP 2015 keeps the 1997 UBC form of the spectrum. You choose:

  • Seismic zone: zone 4 (Z = 0.4) for most of the country, or zone 2 (Z = 0.2) for Palawan and the Sulu islands.
  • Soil profile: SA to SE (Table 208-2).
  • Seismic source type A, B or C and the distance to it in km (zone 4 only). These give the near-source factors Na and Nv (Tables 208-5 and 208-6), interpolated in the distance.
  • Structural system, which sets R (Table 208-11).

Struxt3D shows the resulting Ca and Cv (Tables 208-7 and 208-8) under the inputs.

Soil profileCa zone 4Cv zone 4Ca zone 2Cv zone 2
SA hard rock0.32Na0.32Nv0.160.16
SB rock0.40Na0.40Nv0.200.20
SC very dense soil, soft rock0.40Na0.56Nv0.240.32
SD stiff soil0.44Na0.64Nv0.280.40
SE soft soil0.36Na0.96Nv0.340.64
Source typeNa at 2 / 5 / 10 kmNv at 2 / 5 / 10 / 15 km
A (M ≥ 7, high slip rate)1.5 / 1.2 / 1.02.0 / 1.6 / 1.2 / 1.0
B (other faults)1.3 / 1.0 / 1.01.6 / 1.2 / 1.0 / 1.0
C (M < 6.5, low slip rate)1.01.0

The design spectrum (Figure 208-3) rises from Ca at T = 0 to 2.5Ca at T0 = 0.2Ts, stays flat to Ts = Cv/2.5Ca, then falls as Cv/T. Struxt3D divides it by R and keeps it above the static base-shear limits 0.11Ca (eq. 208-6) and, in zone 4, 0.8ZNv/R (eq. 208-7).

012340.000.250.500.751.00 Period T (s) Sa (g) ElasticDesign, R = 8.5
The default seismic inputs (Zone 4, soil SC, Ca = 0.40, Cv = 0.56): elastic spectrum dashed, the design spectrum Struxt3D applies in blue. Change the inputs in Supports & loads › Earthquake.
Structural systemRTable 208-11 system
Ductile moment frame8.5Special moment-resisting frame (SMRF)
Ordinary moment frame3.5Concrete OMRF (steel OMRF is 4.5)
Braced frame6.4Special concentrically braced frame, building frame system
Walls or core5.5Concrete shear walls, building frame system
Elastic1.0—

Materials and sections

MaterialGrades offered (default first)
SteelASTM A992 Gr 50 (345 MPa), A36 (248 MPa), A572 Gr 50 (345 MPa)
Concretef′c 28 MPa (4000 psi), 21 MPa (3000 psi), 35 MPa; Ec = 4700√f′c
Reinforcementfy = 414 MPa (PNS 49 Grade 60)
Glulam24F-V4, 20F-V7

Sections are the US W-shapes and HSS, as in AISC. φ factors are the ACI and AISC ones: 0.90 for steel flexure, 0.90 / 0.65 / 0.75 for concrete flexure, tied columns and shear.

Worked example: a five-storey office in Metro Manila

  1. Open the Multi-storey frame template; set five storeys.
  2. In Materials, choose NSCP 2015. Concrete becomes f′c 28 MPa and bars Grade 60.
  3. In Supports & loads, pick Office, keep wind at 69 m/s, turn on Earthquake: zone 4, soil SD, source type A at 8 km (a site near the West Valley Fault, for example), SMRF.
  4. Press F5 and F6. The design results and the report show the NSCP basis note and the ACI/AISC clauses.

Check 1: near-source factors and coefficients

Na = 1.2 + (8 − 5)/(10 − 5) × (1.0 − 1.2) = 1.08; Nv = 1.6 + 0.6 × (1.2 − 1.6) = 1.36Ca = 0.44 × 1.08 = 0.475, Cv = 0.64 × 1.36 = 0.870

Check 2: spectrum ordinates

Ts = 0.870 / (2.5 × 0.475) = 0.73 s; plateau 2.5Ca/R = 1.188 / 8.5 = 0.140 gAt T = 1.2 s: Cv/(T R) = 0.870 / (1.2 × 8.5) = 0.085 g. Floor: max(0.11 × 0.475, 0.8 × 0.4 × 1.36 / 8.5) = 0.052 g, which governs beyond T ≈ 2 s.

Check 3: combinations on the floor

D = 6.41 kPa, L = 2.4 kPa (f1 = 0.5); 1.2D + 1.6L = 7.69 + 3.84 = 11.53 kPa; 1.2D + 0.5L = 8.89 kPa with E or W

Check 4: wind pressure at 10 m

q = 0.613 × 1.00 × 69² × 0.85 = 2.48 kPa; windward wall 0.8q = 1.99 kPa

What you still need to check

  • Importance factor I (Table 208-1): Struxt3D uses I = 1.0. For essential or hazardous facilities (I = 1.5 or 1.25), scale your result or check by hand.
  • Vertical earthquake Ev and the redundancy factor ρ are not included in E.
  • Scaling the response spectrum to the static base shear (90 % for regular, 100 % for irregular structures) is not done; compare the reactions' total with V from eqs. 208-4 to 208-7.
  • Storey drift limits, accidental torsion, irregularity checks and the Ωo combinations.
  • Seismic detailing to ACI 318 Chapter 18 / NSCP 418 for SMRF beams, columns and joints, and AISC 341 for steel.
  • Wind: site-specific speed, exposure B or D, topography (Kzt) and components and cladding.

The response spectrum tutorial explains how the spectrum becomes member forces, and accuracy and limitations lists the solver's assumptions.